Select Your Country or Region

You are now at USA (English)
Home / Products / Pressure Injury Prevention / Alternating Pressure / Nimbus 4

Nimbus 4

Pressure redistribution and comfort

The Nimbus 4 system provides effective active pressure redistribution
(alternating therapy) combined with automatic adjustment to the weight, size and position of the individual. It combines Wound Valve Technology, Heelguard, and automatic adjustment of cell pressures, providing effective pressure redistribution to a wide range of patient management issues.

In clinical use for more than 20 years and used across all care environments, Nimbus Alternating Mattress Replacement Systems are proven to be clinically effective and cost efficient¹-⁸

References:
1. Ward C, Wubbels M, Schembri L (2012) Using Complete Pressure Off-loading and Advanced Wound Care to Treat a Complex Sacral Pressure Ulcer. Poster Presentation
2. Clancy J (2011) Winning the war against pressure ulcers. Poster presentation
3. Malbrain M, Hendriks B, Wijnands P et al (2010) A pilot randomised controlled trial comparing reactive air and active alternating pressure mattresses in the prevention and treatment of pressure ulcers among medical ICU patients. Journal of Tissue Viability 19(1):7-15
4. Finnegan MJ (2008). Comparing the effectiveness of a specialised alternating air pressure mattress replacement system and an air fluidised integrated bed in the management of post- operative flap patients. A randomised controlled study. Journal of Tissue Viability 17(1): February 2008
5. Russell L, Reynolds TM (2000) Randomised controlled trial of two pressure relieving systems. Journal of Wound Care 9(2):52-55
6. Evans D, Land L, Geary A (2000). A clinical evaluation of the Nimbus 3 alternating pressure mattress replacement system. Journal of Wound Care 9(4):181-186
7. Land L, Evans D, Geary A et al (2000) A clinical evaluation of an alternating pressure mattress replacement system in hospital and residential care settings. Journal of Tissue Viability 10(1): 6-11
8. Phillips L (2010) Nimbus range of pressure redistributing mattresses. Wounds UK, 2010, 6 (2): 116-122

* Please check with your local sales representative if the product is available for sale in your country.

Nimbus range pump features

Audible and visual alarms
• The pump includes audible and visual alarms, activating only when genuine intervention is needed for Power Fail, High or Low Pressure and Pump Fault conditions.

Comfort control
• For additional patient comfort, minor adjustments to inflation pressures can be made using a comfort control dial, without affecting therapeutic performance.¹⁶

Infection prevention
• 3 stage filtration provided by the bio-filter ensures only clean air is passed into the mattress.

Nimbus range mattress features

Cover
• Vapor permeable and water resistant 2-way stretch cover offers pressure redistribution and comfort. This loose fitting top cover is attached to the mattress base by concealed zippers to reduce ingress of unwanted fluids. The cover is also flame retardant, easy to clean and can be completely removed for laundering.

Auto-matt sensor pad
• The Auto-Matt sensor pad is designed to adjust cell pressures according to patient weight and positioning on the mattress.

Anti-sink mattress design
• The mattress is made up of 19 deep "figure of 8" designed cells to support patients up to 550 lbs (250 kg), providing active pressure redistribution for all patient types and all categories‎⁹ of tissue damage.

Wound valve technology
• 5 heel cells incorporate Wound Valve technology, allowing the carer to permanently off-load ("float") the vulnerable heel, for those patients with limb ischemia or existing wounds.

Cable management
• Reduces risk of injury to patient and/or carer by removing trailing cables.

Transport facility
• Seals air in the mattress for up to 12 hours, providing a uniform stable surface for patient transportation, moving and handling, nursing procedures and during periods of power failure.

Heelguard
• Dedicated mattress zone where bottom 5 cells provide maximum pressure redistribution through use of unique "power down" straps, keeping pressure at the vulnerable heel lower for longer (Nimbus 4).

CPR facility
• A quick release, single handed operation, the CPR facility enables rapid air deflation for emergencies, short term physiotherapy, moving and handling or storage.

Nimbus Professional additional features

Zoned wound valve technology
• Zoned Wound Valve Technology allows carers to selectively isolate any one of 19 individual cells under a patient’s body, providing an adaptable support surface for the management of highly vulnerable areas such as grafts, burns, heels and ischemic legs.¹, ⁴, ¹³, ¹⁴

Sacral deflate
• Wound Valves in the sacral section can deflate the mattress to assist with nursing procedures including bed-chair transfer, physiotherapy, low-height patient egress and also specialized interventions such as diagnostic imaging.

Head section deflate
• The 3 head cells can be deflated to remove pressure from beneath the head, or for providing access to the head and neck for specialist nursing procedures (e.g. intubation, cannulation and hygiene).

References:
1. Ward C, Wubbels M, Schembri L (2012) Using Complete Pressure Off-loading and Advanced Wound Care to Treat a Complex Sacral Pressure Ulcer. Poster Presentation
4. Finnegan MJ (2008). Comparing the effectiveness of a specialised alternating air pressure mattress replacement system and an air fluidised integrated bed in the management of post- operative flap patients. A randomised controlled study. Journal of Tissue Viability 17(1): February 2008
9. National Pressure Ulcer Advisory Panel, European Pressure Ulcer Advisory Panel and Pan Pacific Pressure Injury Alliance. Prevention and Treatment of pressure ulcers: Clinical practice guideline. Emily Haesler (Ed). Cambridge Media: Osbourne Park, Western Australia; 2014
13. Masterson S, Younger C (2014) Using an alternating pressure mattress to off-load the heels in ICU. British Journal of Nursing 2014; 23(15): 544, 546-549
14. Ashton J, Sturgess J (2006) Back to basics – simple measures resolve a complex wound: Pressure offloading and honey. Poster presentation, EPUAP 2006
16. Arjo Data on File. Product Validation Test Report 10-100037760

* Please check with your local sales representative if the product is available for sale in your country.

Dimensions
Mattress A Name Standard
Mattress A (L x W x H) mm 2085 x 890 x 215 mm
Mattress A (L x W x H) in 82 x 35 x 8.5 in
Mattress A Weight kg 15,5 kg
Mattress B Name Narrow
Mattress B (L x W x H) mm 2085 x 800 x 215 mm
Mattress B (L x W x H) in 82 x 31.5 x 8.5 in
Mattress B Weight kg 14,3 kg
Mattress B Weight lb 31,5 lb
Maximum patient weight kg 250 kg
Maximum patient weight lb 550 lb
Cell Material Polyurethane
Pump
Pump (L x W x H) mm 508 x 220 x 100 mm
Pump (L x W x H) in 20 x 8.75 x 4 in
Weight kg 5,7 kg
Weight lb 12,5 lb
Mode of Operation Continuous
Electrical Rating 35VA
Operating Cycle Time 10 minutes
Shock Protection Class II Type BF
Ingress Protection IP21
Power In 230 VAC, 50Hz
Standards EN60601-1, IEC60601-1

* Please check with your local sales representative if the product is available for sale in your country.

Explore this product

Filter
Filter
Choosing Support Surface Covers

Type: Leave behind / Brochure

Language
DOWNLOAD
Nimbus Range Brochure

Type: Leave behind / Brochure

Language
DOWNLOAD
PIP International Guidelines

Type: Leave behind / Brochure

Language
DOWNLOAD
Instructions for use IR interface

Type: Instructions for use (IFU)

Language
DOWNLOAD
Nimbus 4 Nimbus Professional - Instructions for use

Type: Instructions for use (IFU)

Language
DOWNLOAD
Nimbus 4 Nimbus Professional Quick reference guide - Contols (A4, Portrait, Colour)

Type: Quick Reference Guide (QRG)

Language
DOWNLOAD
Nimbus 4 Nimbus Professional Quick reference guide - Use (A4, Portrait, Colour)

Type: Quick Reference Guide (QRG)

Language
DOWNLOAD
Nimbus Professional Quick reference guide - Prone positioning (A4, Landscape, Colour)

Type: Quick Reference Guide (QRG)

Language
DOWNLOAD
The Science Behind the Support Surface

Type: Clinical evidence brochure

Language
DOWNLOAD

* Please check with your local sales representative if the product is available for sale in your country.

Choosing Support Surface Covers

Type: Leave behind / Brochure

Language
DOWNLOAD
Nimbus Range Brochure

Type: Leave behind / Brochure

Language
DOWNLOAD
PIP International Guidelines

Type: Leave behind / Brochure

Language
DOWNLOAD
The Science Behind the Support Surface

Type: Clinical evidence brochure

Language
DOWNLOAD

* Please check with your local sales representative if the product is available for sale in your country.

Instructions for use IR interface

Type: Instructions for use (IFU)

Language
DOWNLOAD
Nimbus 4 Nimbus Professional - Instructions for use

Type: Instructions for use (IFU)

Language
DOWNLOAD
Nimbus 4 Nimbus Professional Quick reference guide - Contols (A4, Portrait, Colour)

Type: Quick Reference Guide (QRG)

Language
DOWNLOAD
Nimbus 4 Nimbus Professional Quick reference guide - Use (A4, Portrait, Colour)

Type: Quick Reference Guide (QRG)

Language
DOWNLOAD
Nimbus Professional Quick reference guide - Prone positioning (A4, Landscape, Colour)

Type: Quick Reference Guide (QRG)

Language
DOWNLOAD

* Please check with your local sales representative if the product is available for sale in your country.

Arjo technician helps customer

We are here for you!

Can’t find what you are looking for? Let us help.