Skin IQ® 1000
Skin IQ™ Microclimate Manager
An effective and intuitive solution for the prevention and management of pressure injuries.
Microclimate Management (MCM) the critical link to skin integrity• Microclimate refers to the conditions of moisture and temperature at the point(s) of skin/surface interface¹
• Microclimate is a key factor for patients at risk of maceration and skin breakdown
• Excess variation in moisture and/or temperature increases skin sensitivity to the damaging effects of pressure, shear, and friction²
References:
1. National Pressure Ulcer Advisory Panel, European Pressure Ulcer Advisory Panel and Pan Pacific Pressure Injury Alliance. Prevention and Treatment of Pressure Ulcers: Clinical Practice. Guideline. Emily Haesler (Ed). Cambridge Media: Perth, Australia; 2014.
2. International Review. Pressure Ulcer Prevention: Pressure, Shear, Friction and Microclimate in Context. A Consensus Document. London: Wounds International, 2010.
• A waterproof, vapor-permeable top layer that offers a bacterial and viral barrier¹
• Negative Airflow Technology (NAT) continually draws excess moisture away from the skin / mattress interface. Bench studies show that Skin IQ Microclimate Management (MCM) removes 3.8 times more moisture at the skin/mattress interface than the same mattress without Skin IQ MCM²
• Bench studies show that Skin IQ MCM reduces staphylococcus aureus growth by 3.1 logs over a 24 hour period. A percentage reduction of greater than 99.9%.³ *
• Bench studies show that Skin IQ MCM significantly reduces odor at the skin/mattress interface when compared to the same surface without airflow⁴
• Designed for compatibility with pressure redistribution mattresses on the market today (eg, AtmosAir™ 9000 Mattress Replacement System)
Simple features, sophisticated performance
Effective for your patients
• The Skin IQ 1000 bariatric version provides an MVTR of 165/g/m2/hr⁶
• Top layer material helps reduce shear and friction⁷
• Quick, intuitive setup and maintenance
• Low profile design
*The level of treament stated indicates theoretical levels only
1. Arjo Data on File, Test Report Viral Barrier Property of Top Sheet of Skin IQ Coverlet – Test Report 100018376 pg. 3 & Test Report 100019009 pg. 1-7.
2. Arjo Data on File, Study SIQ2010-57. Test Report – Skin IQ Microclimate Manager/Low Air Loss (LAL) Coverlet Functional (Post-Stress) Testing – Test Report 100018343 pg. 6, 12.
3. Arjo Data on File. Test Report – 100077042.
4. Arjo Data on File, Assessment of Skin IQ Microclimate Manager Capability to Mitigate odor – Test Report 100018484.
5. Arjo Data on File, Skin IQ Reusable System Functional Test – Test Report 100014338 pg. 6.
6. Arjo Data on File, Skin IQ Microclimate Manager 60 Day MVTR – Test Report 100016748 pg. 3.
7. Arjo Data on File, Skin IQ Coefficient of Friction – Test Report 100018362 pg. 1.
• Negative Airflow Technology (NAT) continually draws excess moisture away from the skin / mattress interface. Bench studies show that Skin IQ Microclimate Management (MCM) removes 3.8 times more moisture at the skin/mattress interface than the same mattress without Skin IQ MCM²
• Bench studies show that Skin IQ MCM reduces staphylococcus aureus growth by 3.1 logs over a 24 hour period. A percentage reduction of greater than 99.9%.³ *
• Bench studies show that Skin IQ MCM significantly reduces odor at the skin/mattress interface when compared to the same surface without airflow⁴
• Designed for compatibility with pressure redistribution mattresses on the market today (eg, AtmosAir™ 9000 Mattress Replacement System)
Simple features, sophisticated performance
Effective for your patients
• The Skin IQ 1000 bariatric version provides an MVTR of 165/g/m2/hr⁶
• Top layer material helps reduce shear and friction⁷
• Quick, intuitive setup and maintenance
• Low profile design
*The level of treament stated indicates theoretical levels only
1. Arjo Data on File, Test Report Viral Barrier Property of Top Sheet of Skin IQ Coverlet – Test Report 100018376 pg. 3 & Test Report 100019009 pg. 1-7.
2. Arjo Data on File, Study SIQ2010-57. Test Report – Skin IQ Microclimate Manager/Low Air Loss (LAL) Coverlet Functional (Post-Stress) Testing – Test Report 100018343 pg. 6, 12.
3. Arjo Data on File. Test Report – 100077042.
4. Arjo Data on File, Assessment of Skin IQ Microclimate Manager Capability to Mitigate odor – Test Report 100018484.
5. Arjo Data on File, Skin IQ Reusable System Functional Test – Test Report 100014338 pg. 6.
6. Arjo Data on File, Skin IQ Microclimate Manager 60 Day MVTR – Test Report 100016748 pg. 3.
7. Arjo Data on File, Skin IQ Coefficient of Friction – Test Report 100018362 pg. 1.
Weight and dimensions | |
---|---|
Weight capacity kg | 453,6 kg |
Weight capacity lb | 1000 lb |
Overall Length mm | 2134 mm |
Overall Length in | 84 in |
Overall Width mm | 1219 mm |
Overall Width in | 48 in |
Depth/Height of surface mm | 178 mm |
Depth/Height of surface in | 7 in |
Coverlet Height mm | 6,35 mm |
Coverlet Height in | 0,25 in |
Packaging | Single unit |
Electrical | |
Voltage | 100 - 240 VAC |
Frequency | 50 - 60 Hz |
Ampere Rating | 0.5A |
Power Supply | DCV, Reusable and cord |
Operating Temperature Range C | 14 - 35 °C |
Operating Temperature Range F | 57.2 - 95 °F |
Storage Temperature Range C | -29 - 60 °C |
Storage Temperature Range F | 20.2 - 140 °´F |
Classification | B |
Standards | IEC60601-1:2006 |
Explore this product
Filter
Filter
Bariatric solution brochure
Type: Leave behind / Brochure
Skin IQ 1000 Instructions for use Microclimate Manager
Type: Instructions for use (IFU)
Skin IQ Case Study Brochure
Type: Case study
Bariatric solution brochure
Type: Leave behind / Brochure
Skin IQ Case Study Brochure
Type: Case study
Skin IQ 1000 Instructions for use Microclimate Manager
Type: Instructions for use (IFU)