AtmosAir Velaris
Designed for comfort without compromising therapy in both reactive and active mode
AtmosAir Velaris accommodates a 'One Surface Strategy' as it can replace all but the most advanced automatic surfaces with one easy to use, flexible mattress system.
AtmosAir Velaris® is a flexible and cost-effective adaptable alternating pressure system that can be used across a wide range of patient risk categories, and is suitable for all care settings.More than just a hybrid: When connected to the pump, AtmosAir Velaris transforms to an alternating therapy surface that can achieve full pressure offloading¹ with AltoVac® technology while maintaining high comfort levels.
Without the pump attached, it provides reactive pressure redistribution through the ARM® (Air Redistribution Module) to maintain comfort and pressure levels in each air cell.
This adaptable system enables you to offer customised therapy for patients at low to high Pressure Injury (PI) risk, without the need to change the support surface. As a result, this can streamline workflows and save you time - because when it comes to pressure injury prevention, time is everything.
Dementia-friendly design: Designed with a range of features to support comfort, the AtmosAir Velaris is accredited by the Dementia Services Development Centre (DSDC) as a dementia-friendly product with a 1A rating.
The Velaris range includes the AtmosAir Velaris Standard Mattress, AtmosAir Velaris Plus Mattress, AtmosAir Velaris Stretcher Trolley (ST) Mattress and AtmosAir Velaris Seat Cushion, all of which offer reactive pressure redistribution with ARM. In addition, both the standard and Plus mattresses can connect to the AtmosAir Velaris pump to deliver active alternating therapy with AltoVac.
Reference:
1. Clark M (2021), Comparative Testing of Interface Pressure Performance of Seven Hybrid Surface Technologies Using a Weighted Mannequin. Arjo whitepaper.
ARM®
Redistributes air between the cells to maintain a predefined level of pressure.
AltoVac®
Connect the pump to deliver active (alternating pressure) therapy with AltoVac® vacuum technology, which achieves full pressure offloading when cells are compressed.
Foam filled air cells
A top layer of visco-elastic foam and a base layer of firm foam is built into each air cell, offering comfort while eliminating the need for an additional foam layer between the patient and the air cells which can compromise active therapy.
Dedicated Skin IQ® cable port
For integrated microclimate management.
Automatic dimming LEDs
Pump lights automatically dim when built-in sensors detect dark ambience.
QuietConceptâ„¢
Silent operation at 19 dB(A).
6° sloped heel zone
Designed to support pressure offloading from the vulnerable heel area, which can be further enhanced with alternating therapy.
Firm foam perimeter
Offers support for getting in and out of bed.
Covers designed for infection control
Available in Dartex Reliant or Premium covers. Both cover options feature welded seams and handles, cable management loops, watershed flap over the zipper, and 360° zip allowing complete removal for ease of cleaning and disinfection.
Plus size mattress option
The AtmosAir Velaris pump works with AtmosAir Velaris standard and plus size mattresses, enabling active therapy for patients up to 454kg (1000 lbs).
Redistributes air between the cells to maintain a predefined level of pressure.
AltoVac®
Connect the pump to deliver active (alternating pressure) therapy with AltoVac® vacuum technology, which achieves full pressure offloading when cells are compressed.
Foam filled air cells
A top layer of visco-elastic foam and a base layer of firm foam is built into each air cell, offering comfort while eliminating the need for an additional foam layer between the patient and the air cells which can compromise active therapy.
Dedicated Skin IQ® cable port
For integrated microclimate management.
Automatic dimming LEDs
Pump lights automatically dim when built-in sensors detect dark ambience.
QuietConceptâ„¢
Silent operation at 19 dB(A).
6° sloped heel zone
Designed to support pressure offloading from the vulnerable heel area, which can be further enhanced with alternating therapy.
Firm foam perimeter
Offers support for getting in and out of bed.
Covers designed for infection control
Available in Dartex Reliant or Premium covers. Both cover options feature welded seams and handles, cable management loops, watershed flap over the zipper, and 360° zip allowing complete removal for ease of cleaning and disinfection.
Plus size mattress option
The AtmosAir Velaris pump works with AtmosAir Velaris standard and plus size mattresses, enabling active therapy for patients up to 454kg (1000 lbs).
AtmosAir Velaris Range | |
---|---|
Top cover fabric options | Dartex Reliant or Premium |
PVC free | Yes |
Welded seams & handles as standard | Yes |
Mattress fire tests*** | BS7177 (BS597-1, BS597-2, BS6807 Clause 9-Ignition Source 5), 16CFR1632, 16CFR1633, CAL TB 129 |
Firesock as standard | Yes |
AtmosAir Velaris Standard Mattress | |
Top cover fabric options | Dartex Reliant or Premium |
Standard sizes* (W x L x H) | 810 x 2000 x 180 mm (31 x 78 x 7 in) |
Standard sizes* (W x L x H) | 860 x 1980 x 180 mm (34 x 78 x 7 in) |
Standard sizes* (W x L x H) | 880 x 2020 x 180 mm (35 x 80 x 7 in) |
Standard sizes* (W x L x H) | 880 x 2140 x 180 mm (35 x 84 x 7 in) |
Standard sizes* (W x L x H) | 900 x 2000 x 180 mm (35 x 79 x 7 in) |
Standard sizes* (W x L x H) | 1070 x 2000 x 180 mm (42 x 79 x 7 in) |
Ability to connect to AtmosAir Velaris alternating pressure pump | Yes |
Weight of mattress | 15.0 kg (33 lb) - 17.5 kg (39 lb) |
Maximum patient weight | 250 kg (550 lb) |
Expected service life | 5 years |
AtmosAIr Velaris Plus Mattress | |
Top cover fabric options | Dartex Reliant or Premium |
Standard sizes* (W x L x H) | 1220 x 2140 x 180 mm (48 x 84 x 7 in) |
Ability to connect to AtmosAir Velaris alternating pressure pump | Yes |
Weight of mattress | 24 kg (53 lb) |
Maximum patient weight | 454 kg (1000 lb) |
AtmosAir Velaris Alternating Pressure Pump | |
Size (W x L x H) | 337 x 107 x 200 mm (13.3 x 4.2 x 7.9 in) |
Weight | 4.1 kg (9 Ib) |
Alternating cycle time | 10 minutes |
Supply voltage | 100 - 230 V |
Power input | 3 - 46 VA |
IP rating | IP22 |
Case material | PC ABS |
Sound output | 19 dBA |
Lock out control panel feature | Yes |
Suppress audible Alarm option | Yes |
Alarm pause | Yes (15 mins) |
Skin IQ adapter part number** | Power cable 636377 |
Expected service life | 7 years |
AtmosAir Velaris Stretcher Trolleys (ST) Mattress | |
Top cover fabric options | Dartex Reliant or Premium |
Standard sizes* (W x L x H) | 660 x 1910 x 130 mm (26 x 75 x 5 in) |
Standard sizes* (W x L x H) | 670 x 1950 x 130 mm (26 x 77 x 5 in) |
Standard sizes* (W x L x H) | 762 x 1910 x 130 mm (30 x 75 x 5 in) |
Ability to connect to AtmosAir Velaris alternating pressure pump | No |
Weight of mattress | 9 kg (20 lb) - 10 kg (22 lb) |
Maximum patient weight | 250 kg (550 lb) |
Expected service life | 5 years |
AtmosAir Velaris Seat Cushion | |
Top cover fabric options | Dartex Reliant or Premium |
Standard sizes* (W x L x H) | 432 x 432 x 100 mm (17 x 17 x 4 in) |
Standard sizes* (W x L x H) | 457 x 457 x 100 mm (18 x 18 x 4 in) |
Ability to connect to AtmosAir Velaris alternating pressure pump | No |
Weight of cushion | 1.5 kg (3 lb) |
Maximum patient weight | 250 kg (550 lb) |
Expected service life | 5 years |
* Please contact your Arjo representative to enquire about product and size availability | - |
** Skin IQ coverlet and pump connector sold separately | - |
*** Standards not available for Velaris Seat Cushion | - |
Explore this product
Filter
Filter
AtmosAir Velaris Specification Sheet
Type: Specifications sheet / Flyer
AtmosAir Velaris Quick reference guide - Cleaning and disinfection (A4, Portrait, Colour)
Type: Quick Reference Guide (QRG)
AtmosAir Velaris Quick reference guide - Controls (A4, Portrait, Colour)
Type: Quick Reference Guide (QRG)
The Science Behind the Support Surface
Type: Clinical evidence brochure
AtmosAir Velaris Performance Testing Whitepaper
Type: Whitepaper
AtmosAir Velaris S3I Performance Testing Whitepaper
Type: Whitepaper
AtmosAir Velaris Specification Sheet
Type: Specifications sheet / Flyer
The Science Behind the Support Surface
Type: Clinical evidence brochure
AtmosAir Velaris Performance Testing Whitepaper
Type: Whitepaper
AtmosAir Velaris S3I Performance Testing Whitepaper
Type: Whitepaper
AtmosAir Velaris Quick reference guide - Cleaning and disinfection (A4, Portrait, Colour)
Type: Quick Reference Guide (QRG)
AtmosAir Velaris Quick reference guide - Controls (A4, Portrait, Colour)
Type: Quick Reference Guide (QRG)