Citadel
Integrated system for high dependency patients
Citadel Patient Care System, built upon a universal platform and designed to transition from a non-integrated to an integrated system, provides flexible patient care for hospitals that demand safety, security and efficiency from their medical bed frames and therapeutic mattresses.
One system. Multiple acuities.The bed frame is the centre of patient care during their stay in the hospital. It is an essential tool which may help promote rehabilitation while helping to reduce patient or caregiver injuries. Both the bed frame and mattress need to work in harmony throughout a hospital and across acuity levels to provide support for the patients and clinicians using them. Citadel has been designed and built for this purpose.
The benefits of integration
Integration provides communication between the bed frame system and patient therapy system which delivers:
• One button CPR which delivers the CPR mode simultaneously to the mattress and the frame
• Automatic pressure compensation in the seat section when the head of bed is adjusted
• Restricts turning when the head of bed exceeds 30 degrees
• Restricts turning when one or more of the side rails is lowered
Additionally, the paired therapy system and bed frame offer bespoke mattress and frame design to help address entrapment concerns that result from using a frame and a mattress from two different suppliers.
INTEGRATED WEIGHING SCALE
Digital display weighs up to 270 kg (+/– 500 g). Patient weight is visually displayed for 10 seconds only to help protect patient dignity.
VARIZONE PATIENT MOVEMENT DETECTION SYSTEM
Can be set to alarm and detect when undesired movement of the patient occurs.
ANTI ENTRAPMENT SYSTEM
Detects obstructions under the sleep deck during bed articulation and stops the downward movement of the bed.
SAFESET
Provides visual alerts:
Side rail position
Brake status
Bed height
If VariZone is armed
ONE BUTTON CHAIR POSITION
Citadel can be articulated into a chair position lowering the legs and abdomen to help improve patient comfort.
30 DEGREE BACKREST AUTO PAUSE
Digital head of bed angle display. Automatic pause at 30 degree head elevation.
C100 ACTIVE THERAPY SUPPORT SURFACE
Four-zone pressure adjustment
Patient height and weight pre-sets
Patient turn
Firm mattress
Patient transport mode
Head & seat deflate options
X-ray sleeve
C200 SUPPORT SURFACE Offers all of the C100 features, plus the following:
Pulsation and Alternating Pressure Therapy
Continuous 20° turn for patient repositioning
Digital display weighs up to 270 kg (+/– 500 g). Patient weight is visually displayed for 10 seconds only to help protect patient dignity.
VARIZONE PATIENT MOVEMENT DETECTION SYSTEM
Can be set to alarm and detect when undesired movement of the patient occurs.
ANTI ENTRAPMENT SYSTEM
Detects obstructions under the sleep deck during bed articulation and stops the downward movement of the bed.
SAFESET
Provides visual alerts:
Side rail position
Brake status
Bed height
If VariZone is armed
ONE BUTTON CHAIR POSITION
Citadel can be articulated into a chair position lowering the legs and abdomen to help improve patient comfort.
30 DEGREE BACKREST AUTO PAUSE
Digital head of bed angle display. Automatic pause at 30 degree head elevation.
C100 ACTIVE THERAPY SUPPORT SURFACE
Four-zone pressure adjustment
Patient height and weight pre-sets
Patient turn
Firm mattress
Patient transport mode
Head & seat deflate options
X-ray sleeve
C200 SUPPORT SURFACE Offers all of the C100 features, plus the following:
Pulsation and Alternating Pressure Therapy
Continuous 20° turn for patient repositioning
Angles | |
---|---|
Head down tilt | 12° |
Foot down tilt | 12° |
Backrest angle | 62° |
Backrest pause | 30° |
Thigh angle | 20° |
Calf angle | 16° |
Product Specifications | |
Safe working load kg | 270 kg |
Safe working load lb | 595 lb |
Maximum patient weight kg | 227 kg |
Maximum patient weight lb | 500 lb |
Safety standard IEC | IEC 60601-1:2005 + AMD1:2012, IEC 60601-2-52:2009 + AMD1:2015 |
Safety standard ANSI/AAMI | ANSI/AAMI ES60601-1:2005 + AMD1:2012 * |
Safety standard CAM/CSA | CAN/CSA-C22.2 No. 60601-1:14 |
EMC | EN 60601-1-2:2002, 2007 |
Mattress thickness mm | 150 mm |
Mattress thickness in | 6 in |
Overall Product weight (approx.) kg | 200 kg |
Overall Product weight (approx.) lb | 441 lb |
Mattress and control unit weight (approx) kg | 41 kg |
Mattress and control unit weight (approx) lb | 90 lb |
Base configuration | Head end panel ‘off’ base (HOB) |
Electrical Data | |
Ingress protection | Ingress protection IPX4 |
Shock protection | Class 1, Type B Applied Part |
EMC | IEC 60601-1-2:2014 + AMD1:2020 |
Duty Cycle | 10% (2 min on, 18min off) |
Battery backup | 2 x 12v series connected, 5Ah |
Power in (9.5A) | 9.5A max at 115 VAC 60Hz |
Power in (4.5A) | 4.5A max at 230 VAC 50Hz |
Power in (4.5A) | 4.5A max at 230 VAC 60Hz |
Dimensions | |
Overall standard length (HOD) cm | 230 cm |
Overall standard length (HOD) in | 90,6 in |
Overall length mm | 1030 mm |
Overall length in | 40,55 in |
Mattress length standard mm | 2020 mm |
Mattress length standard in | 79,53 in |
Mattress width standard mm | 880 mm |
Mattress width standard in | 34,65 in |
Overall length, extended (HOD) cm | 242 cm |
Overall length, extended (HOD) in | 95,3 in |
Mattress length, extended mm | 2140 mm |
Mattress length, extended in | 84,25 in |
Top height (with 125 mm castors) mm | 780 mm |
Top height (with 125 mm castors) in | 30,7 in |
Low height (with 125 mm castors) mm | 340 mm |
Low height (with 125 mm castors) in | 13,4 in |
In bed length standard cm | 202 cm |
In bed length standard in | 80 in |
In bed length extended cm | 214 cm |
In bed length extended in | 84 in |
Mattress width cm | 88 cm |
Deck Height (150mm / 6 in castors) cm | 36 cm to 80 cm |
Deck Height (150mm / 6 in castors) in | 14.1 to 31.5 in |
Deck Height (125mm / 5 in castors) cm | 34 cm to 78 cm |
Deck Height (125mm / 5 in castors) in | 13.3 to 30.7 in |
Overall width cm | 103 cm |
Overall width in | 40.6 in |
Electrical | |
Power in (230V) | 1.5A max at 230V |
Power in (120V) | 3A ,ax at 120V |
Power in (60Hz) | AC 50/60Hz |
Patient weighing system | |
Minimum verification interval (scale division) g | 500 g |
Minimum verification interval (scale division) lb | 1 lb |
Minimum capacity kg | 10 kg |
Minimum capacity lb | 22 lb |
Maximum capacity kg | 270 kg |
Maximum capacity lb | 595 lb |
Approvals 1 | Directive 2014/31/EU, accuracy class lll |
Scale rating 2 | Class lll |
1. Applicable for countries an associate in CEN region | - |
2. Applicable to rest of world | - |
Explore this product
Filter
Filter
Medical beds accessories Brochure
Type: Leave behind / Brochure
Citadel Bed frame system - Instructions for use
Type: Instructions for use (IFU)
The Science Behind the Support Surface
Type: Clinical evidence brochure
Medical beds accessories Brochure
Type: Leave behind / Brochure
The Science Behind the Support Surface
Type: Clinical evidence brochure
Citadel Bed frame system - Instructions for use
Type: Instructions for use (IFU)